October 5, 2026

Key takeaways from EIA Nordic 2026

Conference highlights

The technical sessions spanned the full research lifecycle, from early-stage conceptual frameworks and initial test runs to fully deployed, real-world solutions.

Vasman found it interesting to see how partner countries approach energy distribution and district heating networks under differing local regulatory, geographical and operational contexts.

Buildings, as major energy users, were in focus alongside smart grid and grid stability algorithms, reinforcement learning and digital twins.

The paper

At the conference, Vasman presented the paper Data Requirements for Heating Energy Efficiency Evaluation in Buildings, by Sofia Vasman, Dr Tuule Mall Parts and Prof. Martin Thalfeldt (Department of Civil Engineering and Architecture, TalTech) and Prof. Eduard Petlenkov (Department of Computer Systems, TalTech).

While data-driven heating evaluation methods are discussed in the literature, existing research rarely considers metering and sensor infrastructure readiness across actual building portfolios. The authors categorised evaluation methods from 21 studies into a structured applicability framework, based on input configuration sets, and evaluated them on a 25-building university campus portfolio.

The key findings:

•         More variables over pure granularity. Pushing for sub-hourly data logging is not always the best first step. In the portfolio testing, integrating additional weather variables (such as solar irradiance and wind speed) at daily resolution unlocked advanced evaluation methods across 72% of buildings. In contrast, sub-hourly dynamic methods were restricted to just 8% of buildings due to logging constraints.

•         Single-input bottlenecks. Methods requiring specific single inputs, such as dedicated occupancy sensors, were limited to only 12% of campus buildings, showing how single-sensor dependencies can severely restrict portfolio-wide analysis.

•         Strategic time-series management. To maximise data use across diverse applications (such as intelligent control, fault detection with root-cause analysis and energy benchmarking), the focus should shift towards modern time-series management and structured storage strategies. This ensures that variables displayed in Building Management Systems (BMS) are purposefully logged and physically meaningful to current building operations, while preventing “data swamps” through intentional data governance.

Special thanks

Vasman thanks the General Chairs, Rúnar Unnþórsson (University of Iceland), Bo Nørregaard Jørgensen (University of Southern Denmark) and Zheng Grace Ma (SDU Center for Energy Informatics), the entire organising team, the session chairs and the keynote speakers for pulling together such a seamless and impactful event. More on the organisers.

And her pro tip for anyone attending a conference in Iceland in the future: always pack a swimsuit.

Latest Articles

More updates from the ENTRANCE project

Lightweight gray-box models for accurate indoor temperature prediction
20 Oct 2026

Lightweight gray-box models for accurate indoor temperature prediction

Aalborg University has developed compact gray-box models that accurately predict indoor temperatures using limited building data. Lightweight and computationally efficient,...

Read More
Assessing Thermal Flexibility Potential in a Multipurpose Building in Norway
24 Jun 2026

Assessing Thermal Flexibility Potential in a Multipurpose Building in Norway

At the VII International Scientific and Technical Conference (Krakow, 20–22 May 2026), ENTRANCE researcher Aayam Chaulagain presented a study on...

Read More
Research Forum #1
29 May 2026

Research Forum #1

The first Research Forum session featured Edoardo Scalera (Aalto University / TalTech), presenting his research within the ENTRANCE project on...

Read More